150mm Party Wall Cavity Stop Socks 155mm x 250mm x 1200mm
Product Code Suitable for Sleeve Colour Masonry Fire Performance Compression Dimensions Lengths per pack Packs per pallet
Cavity Width Fire Integrity Insulation Required
PWCSS150 150mm Red 4 hrs 4 hrs Friction 130 x 250 x 1200mm 6 10
Cavity fire barrier for masonry construction
» Up to 4 hours fire integrity
» Horizontal and vertical options
» Specified in terraced, semi-detached, apartments and major projects
» Meets requirements of Robust Detail Part E and Approved Document B
» Maximum cavity width available: 300mm
» Easily installed with compression fit; no mechanical fix is required
» Third-party certificated by Certifire
Application
ARC Cavity Stop Sock restricts the spread of smoke and flames within the cavity of external masonry walls. It is ideally suited for providing a cavity barrier within the external wall cavity, in line with a separating wall or floor as specified in Approved Document B, and for closing the cavity at eaves level.
Party Wall Junction
ARC’s Party Wall Cavity Stop Sock is designed for use at the party wall junction; fitted in the external wall cavity, with a minimum 50mm overlap either side of the party wall cavity. At 250mm wide, ARC PWCSS
range is suitable for use with party
wall cavities up to 150mm wide.
These wider barriers do not require
a compression fit, and are supplied
with a 5mm compression to allow
for site anomolies.